A/d/s/ P850 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Récepteurs de médias en voiture A/d/s/ P850. a/d/s/ P850 Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
SP850
Six Zone Downloadable Panel
Installation & Programming
Manual
Programmed through the keypads
or with the ScanPro Downloader Software
Use with KP600F LED KYPD
KP600L LCD KYPD
OR KEYSWITCH
P/N 64812822 A PDF 9/15/97
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Six Zone Downloadable Panel

1SP850Six Zone Downloadable PanelInstallation & ProgrammingManualProgrammed through the keypadsor with the ScanPro Downloader SoftwareUse with KP6

Page 2 - Table of Contents

10SEC 3: KEYPAD OPERATION & PROGRAMMING INSTRUCTIONS3.0 INTRODUCTIONWhether you are an experienced installer/programmer or anewcomer, you will fin

Page 3

11There are a total of five parameters to be programmed insetting the time and date of the system. These five param-eters must be programmed in conse

Page 4 - 1.1 INSTALLATION

12SEC 4: COMPLIANCE INFORMATIONU.S. INSTALLATION CONSIDERATIONSFollow the instructions below when installing and programming an SP850Alarm Control Pan

Page 5 - 1.2 TROUBLESHOOTING

13CONDITION SCANPRO EXTENDED 4+2 SILENT ADEMCODOWNLOADER KNIGHT SUPERFASTScenario #1 Account 1234A) Trip on Zone 1 03-1234 [ 11] [001] A cc. 1234

Page 6 - 1.4 SPECIFICATIONS

14NOTES: The following corresponds to Table 2 information on page 10.For Ademco Highspeed Format, the following reporting codes must be used. Report

Page 7 - 1.7 OPTIONAL ACCESSORIES

15SP850 PROGRAMMING WORKSHEET CUSTOMER NAME_________________________CUSTOMER ADDRESS________________________ACCOUNT #________ScanPro PROGRAMITEM # L

Page 8 - PRESSED SIMULTANEOUSLY

1649 136-140TIMER REPORT [month] [weekday] [day] [hour] [min] 136MNTH137W/DAY138DAY139HOUR140MIN. Weekdays=1-7 (Sunday=1 - Saturday=7)All Blank=24Hr

Page 9

17Enter a value from the list below to select the transmissionformat for each telephone number.1 = Fast, 2300 Hz. handshake, 1800 Hz. data, 20 pps.2

Page 10

18STEP 19-22 100-107 KEYPAD EMERGENCY CODES(Two-digit 1-9, A-F)Codes sent when the keypairs are activated.Reporting for these events is enabled i

Page 11

19STEP 37 122 BYPASS CODE (One-digit 1-9, A-F)Code reported whenever the system is armed with a bypassedzone (See Memory Location 196). Programmin

Page 12 - SEC 4: COMPLIANCE INFORMATION

2Table of ContentsSEC 1: INSTALLATION INSTRUCTIONS ...41.0 SYSTEM DESCRIPTION ...

Page 13

20THIS NOTE APPLIES TO LOCATION 141 AND 142NOTE: Dual Bell/Siren operation is programmed either by se-lecting assignable out #1 for Burglary and assi

Page 14

21INSTALLER / USER ACCESS CODESSTEP 54 145-148 INSTALLER CODEA four digit code used to provide access to the installer levelof programming.Default v

Page 15 - SP850 PROGRAMMING WORKSHEET

22ZONE CONFIGURATIONSSTEP 74 193 FAST RESPONSE ZONES (1-6)Select zones which will use the Fast Zone Response Timeprogrammed in location 126.STEP

Page 16 - 12345678

23STEP 87 206 FUNCTION SELECT GROUP 21 Auto bell test 2 No F/C kypd trouble3 DTMF tone dial 4 European rotary dial5 5-7 sec. DOB output 6 Disable

Page 17 - SEC 5: PROGRAMMING STEPS

SEC 6: LIMITED WARRANTYWARRANTY AND LIABILITY LIMITATIONSAND DISCLAIMERLIMITED WARRANTYSentrol, Inc., warrants to the purchaser that under normal use

Page 18

3CANADIAN INSTALLATIONS NOTE: The Canadian Department of Communications la-bel identifies certified equipment. This certification meansthat the eq

Page 19 - PROGRAMMABLE DELAYS

41.0 SYSTEM DESCRIPTIONThe ARROWHEAD Model SP850 is a multi-zone controlpanel/digital communicator alarm system. The SP850 canbe custom tailored for

Page 20 - This is also the "Single

514. The system may now be Disarmed and Armed from theKP600F/L using the Primary (Factory Programmed) User code1111. Leave system disarmed.15. TESTIN

Page 21 - INSTALLER / USER ACCESS CODES

61.3 WIRING TERMINALSTerminal Description1 & 2 AC Power, 16.5VAC, 20VA3 Bell Negative ( - )4 Bell Positive (+) Output 12VDC nominal5 Auxiliary Po

Page 22 - ZONE CONFIGURATIONS

71.5 "TEL-REMOTE" TELEPHONE ACCESSThe SP850 control panel can be interrogated and statuschanged from a remote touchtone telephone. The sys

Page 23 - RESERVED PROGRAM LOCATIONS

8GENERAL2.0 INTRODUCTIONThe EEPROM in the SP850 may be programmed eitherby remote programming using ScanPro Uploading/Down-loading software, a KP600L

Page 24 - SEC 6: LIMITED WARRANTY

92.6 PROGRAMMING NUMERIC DATAThe following example shows how to program a telephonenumber. Let’s program the primary phone number to dial3647200.A rev

Commentaires sur ces manuels

Pas de commentaire